Every OxyRevo chamber we sell is CE certified and UKCA verified
OxyRevo chambers are made by Zhuji Belecon Health Technology Co., Ltd. The manufacturer holds 21 certification and test documents covering the chambers, compressors, tanks and inflatable bags. Every document below is listed with its certificate number, the report behind it, the issuing body and its expiry date.
WHY RECOVATHLETE CARRIES THIS
RecovAthlete has been an authorized OxyRevo dealer since 2023. We sell 11 OxyRevo models in the United States. The certificates below are issued to the manufacturer and cover the full OxyRevo range, including models we do not stock.
What each certification means
CE certification covers European safety rules for machinery, electrical parts and pressure equipment. Issued by Ente Certificazione Macchine (ECM) in Italy.
UKCA verification covers the equivalent United Kingdom regulations. Issued by ICR Polska Co. Ltd.
ISO 13485:2016 is the quality standard for medical device makers. It checks manufacturing, testing and record keeping.
Technical construction files hold the engineering data and risk assessments behind the CE and UKCA marks.
EMC testing checks the compressor and dryer do not interfere with other electronics in your home.
RoHS and REACH testing confirms the foam, seals and fabric contain no restricted chemicals.
IMPORTANT:
OxyRevo chambers are CE certified and UKCA verified. They are not FDA cleared. If you need an FDA cleared chamber, call us and we will point you to the models that carry that clearance.
1. CE certificates and verifications
| # |
Type |
Certificate no. |
Product and models |
Associated TCF / test report no. |
CE directive |
Standards verified |
Issued |
Expires |
| 1 |
CE Certificate |
0P230407.ZBHUW55 |
Oil free air compressor and air pump. AE01 to AE08, AP01 to AP08, O2ILS14, O2ILS15, O2ILH15, O2ILH16, O2ILH18, O2ILH20 |
MD-TCF-230407-45790 TEZJ23040745791 |
2006/42/EC Machinery 2014/35/EU Low Voltage 2014/30/EU EMC |
EN ISO 12100:2010, EN 60204-1:2018, EN 1012-1:2010, EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019, EN IEC 61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A2:2021 |
07 Apr 2023 |
06 Apr 2028 |
| 2 |
CE Verification |
0P230407.ZBHUW53 |
Stainless steel tank. Quest 30 to Quest 90 Pro, Space series, Delux Pod, Delux Combo, Delux Pro, O2ILH, O2ILM, O2IL Pro, O2IL Fly series |
TPZJ23040745788 |
2014/68/EU Pressure Equipment |
EN 12953-1:2012, EN 14222:2021 |
07 Apr 2023 |
06 Apr 2028 |
| 3 |
CE Certificate |
0P230407.ZBHUW56 |
Air refrigerator dryer (dehumidifier). ZLA01 to ZLA06, LQ01 to LQ06 |
MD-TCF-230407-45792 TEZJ23040745793 |
2006/42/EC Machinery 2014/35/EU Low Voltage 2014/30/EU EMC |
EN ISO 12100:2010, EN 60204-1:2018, EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019, EN IEC 61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A2:2021 |
07 Apr 2023 |
06 Apr 2028 |
| 4 |
CE Attestation |
0P230407.ZBHUW54 |
Inflatable bag. Elite, Apex, Forward, Heal, Heal Multi, OXY, O2ILS series |
TGZJ23040745789 |
2001/95/EC General Product Safety |
EN ISO 23537-1:2016+A1:2018, EN ISO 23537-2:2016 |
07 Apr 2023 |
06 Apr 2028 |
Issued by Ente Certificazione Macchine (ECM), Italy, under a voluntary non-notified procedure per European Commission note of 14 September 2022, Ares(2022)6342894. These documents support the EC Declaration of Conformity, they do not replace it.
2. UKCA verifications of conformity
| # |
Certificate no. |
Serial no. |
Product |
Models |
UK regulation |
Standards |
Issued |
Expires |
| 5 |
ICR/VC/HM2503215 |
013434 |
Air dehumidifier |
ZLA01 to ZLA08, LQ01 to LQ08 |
Electrical Equipment (Safety) Regulations 2016 EMC Regulations 2016 |
BS EN IEC 60335-1:2023+A11:2023, BS EN IEC 55014-1:2021, EN IEC 55014-2:2021, BS EN IEC 61000-3-2:2019+A1:2021, BS EN 61000-3-3:2013+A2:2021 |
26 Mar 2025 |
25 Mar 2030 |
| 6 |
ICR/VC/HM2503216 |
013435 |
Hyperbaric chamber |
Elite and Apex 28, 32, 36, 40. Forward90. Heal40 to Heal90. Quest30 to Quest36. Space60 to Space90. House H1 to H9. Silo S1 to S9. Relax R1 to R9. Monoplace, Multiplace, Pro, Pod, 01 to 06. O2ILH, O2ILM, O2IL Pro, O2IL Fly 75, 80, 86, 90 |
Pressure Equipment (Safety) Regulations 2016 |
BS EN 13445-1:2021 |
26 Mar 2025 |
25 Mar 2030 |
| 7 |
ICR/VC/HM2503217 |
013436 |
Inflatable bag |
Elite and Apex 28, 32, 36, 40. Forward90. Heal40 to Heal90 |
General Product Safety Regulations 2005 |
BS EN ISO 23537-1:2022 |
26 Mar 2025 |
25 Mar 2030 |
| 8 |
ICR/VC/HM2503218 |
013437 |
Oil free air compressor and air pump |
AE01 to AE09, AP01 to AP09, O2ILS14, O2ILS15, O2ILH15, O2ILH16, O2ILH18, O2ILH20 |
Supply of Machinery (Safety) Regulations 2008 |
BS EN ISO 12100:2010, BS EN 60204-1:2018 |
26 Mar 2025 |
25 Mar 2030 |
| 9 |
ICR/VC/HM2503219 |
013438 |
Rest pod |
Quest30 to Quest36. Space60 to Space90. House H1 to H9. Silo S1 to S9. Relax R1 to R9. Monoplace, Multiplace, Pro, Pod, 01 to 06. O2ILH, O2ILM, O2IL Pro, O2IL Fly 75, 80, 86, 90 |
Pressure Equipment (Safety) Regulations 2016 |
BS EN 13445-1:2021 |
26 Mar 2025 |
25 Mar 2030 |
| 10 |
ICR/VC/HM2503220 |
013439 |
Stainless steel tank |
Quest30 to Quest36. Space60 to Space90. House H1 to H9. Silo S1 to S9. Relax R1 to R9. Monoplace, Multiplace, Pro, Pod, 01 to 06. O2ILH, O2ILM, O2IL Pro, O2IL Fly 75, 80, 86, 90 |
Pressure Equipment (Safety) Regulations 2016 |
BS EN 13445-1:2021 |
26 Mar 2025 |
25 Mar 2030 |
Issued by ICR Polska Co. Ltd. on a voluntary basis. The manufacturer applies the UKCA mark after meeting all essential requirements of the relevant UK regulations.
3. ISO quality management certificate
| # |
Certificate no. |
Standard |
Scope |
Issuing body |
Issued |
Registered |
Expires |
| 11 |
AKAQMSMD000884 |
ISO 13485:2016 |
Sales of hyperbaric oxygen chambers and related accessories |
Jiangsu AKA International Standard Certification Co., Ltd. |
08 Dec 2023 |
07 Dec 2023 |
06 Dec 2026 |
4. Technical construction files and MD/LVD reports
| # |
Type |
File / report no. |
Product |
Models |
Prepared by |
Directive |
Standards covered |
Date |
| 12 |
TCF / MD+LVD |
MD-TCF-230407-45790 |
Oil free air compressor and air pump |
AE01 to AE08, AP01 to AP08, O2ILS14, O2ILS15, O2ILH15, O2ILH16, O2ILH18, O2ILH20 |
Shanghai Global Testing Services (GTS) |
2006/42/EC Machinery 2014/35/EU Low Voltage |
EN ISO 12100, EN 1012-1, EN 60204-1 |
06 Apr 2023 |
| 13 |
TCF / MD+LVD |
MD-TCF-230407-45792 |
Air refrigerator dryer (dehumidifier) |
ZLA01 to ZLA06, LQ01 to LQ06 |
Shanghai Global Testing Services (GTS) |
2006/42/EC Machinery 2014/35/EU Low Voltage |
EN ISO 12100, EN 60204-1 |
06 Apr 2023 |
| 14 |
TCF |
TGZJ23040745789 |
Inflatable bag |
Elite, Apex, Forward, Heal, Heal Multi, OXY, O2ILS series |
Shanghai Global Testing Services (GTS) |
2001/95/EC General Product Safety |
EN ISO 23537-1:2016+A1:2018, EN ISO 23537-2:2016 |
06 Apr 2023 |
5. Risk assessment reports
| # |
File no. |
Product |
Models |
Prepared by |
Directive |
Date |
| 15 |
MD-TCF-230407-45790 |
Oil free air compressor and air pump |
AE01 to AE08, AP01 to AP08, O2ILS14, O2ILS15, O2ILH15, O2ILH16, O2ILH18, O2ILH20 |
Shanghai Global Testing Services (GTS) |
2006/42/EC Machinery Directive |
06 Apr 2023 |
| 16 |
MD-TCF-230407-45792 filed as MD-TCF-220510-38556
|
Air refrigerator dryer (dehumidifier) |
ZLA01 to ZLA06, LQ01 to LQ06 |
Shanghai Global Testing Services (GTS) |
2006/42/EC Machinery Directive |
06 Apr 2023 |
6. EMC technical files
| # |
Report no. |
Product |
Models |
Prepared by |
Standards |
Result |
Date |
| 17 |
TEZJ23040745791 |
Oil free air compressor and air pump |
AE01 to AE08, AP01 to AP08, O2ILS14, O2ILS15, O2ILH15, O2ILH16, O2ILH18, O2ILH20 |
Shanghai Global Testing Services (GTS) |
EN IEC 61000-6-4:2019, EN IEC 61000-6-2:2019, EN IEC 61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A2:2021 |
PASS |
06 Apr 2023 |
| 18 |
TEZJ23040745793 |
Air refrigerator dryer |
ZLA-01 to ZLA-06 |
Shanghai Global Testing Services (GTS) |
EN IEC 61000-6-4:2019, EN IEC 61000-6-2:2019, EN IEC 61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A2:2021 |
PASS |
06 Apr 2023 |
7. Material and chemical test reports
| # |
Test |
Report no. |
Sample and material |
Test framework |
Testing lab |
Sample received |
Report date |
Result |
| 19 |
RoHS Test |
SHAEC2110662211 |
Mattress sponge (square sponge, white foam) |
RoHS Directive (EU) 2015/863 amending Annex II to 2011/65/EU. IEC 62321 series |
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd |
27 May 2021 |
01 Jun 2021 |
PASS |
| 20 |
SVHC / REACH |
CZXHL23002411601 |
Silicone seal strip (grey soft plastic) |
REACH. 235 SVHC candidate list substances (ECHA, to Jun 2023). SVHC limit 0.1% by weight |
SGS-CSTC Standards Technical Services (Changzhou) Co., Ltd |
27 Dec 2023 |
05 Jan 2024 |
PASS |
| 21 |
SVHC / REACH |
CZXHL23002180601 |
TPU composite fabric |
REACH. 235 SVHC candidate list substances (ECHA, to Jun 2023). SVHC limit 0.1% by weight |
SGS-CSTC Standards Technical Services (Changzhou) Co., Ltd |
24 Nov 2023 |
04 Dec 2023 |
PASS |
The 11 OxyRevo models we carry
Every model below sits inside the certified scope of the chamber, tank, bag and compressor documents above.
Common questions
Can I get copies of these certificates?
Yes. Call 866-861-6317 or email support@recovathlete.com and tell us which model you are looking at. We will request the documents from OxyRevo for you.
What is the test report number column for?
Each CE certificate rests on an underlying technical file or test report. The report number lets an inspector or insurer trace the certificate back to the raw test data. Sections 4, 6 and 7 list those reports in full.
Does CE certification apply in the United States?
CE and UKCA marks are European and UK schemes. They are not US approvals. They still tell you the chamber was tested to published pressure, electrical and material safety standards by an outside body.
Why do the certificates list models you do not sell?
Certificates are issued to the manufacturer and cover the whole product family. OxyRevo builds more models than we stock in the US. The 11 models we sell all sit inside the certified scope.
Do commercial buyers need extra paperwork?
Clinics and studios sometimes need the ISO certificate and the pressure equipment file for insurance or local permits. Call us before you order and we will collect what your inspector asks for.
QUESTIONS ABOUT CERTIFICATION
Call 866-861-6317, 9am to 6pm EST, Monday to Friday. Or email support@recovathlete.com. You can also book a 30 minute call.
Browse the full OxyRevo range or compare across brands in hyperbaric chambers.